Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Fracture Strength, Failure Types, and Weibull Characteristics of Three-Unit Zirconia Fixed Dental Prostheses After Cyclic Loading: Effects of Veneering and Air-Abrasion Protocols
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 36 , Issue 6
November/December 2016

Pages 901–908


Fracture Strength, Failure Types, and Weibull Characteristics of Three-Unit Zirconia Fixed Dental Prostheses After Cyclic Loading: Effects of Veneering and Air-Abrasion Protocols

Fernanda Campos, DDS, MSc/Rodrigo O.A. Souza, DDS, PhD/Marco A. Bottino, DDS, PhD/Mutlu Özcan, DDS, DMD, PhD


PMID: 27740655
DOI: 10.11607/prd.2524

The required connector dimension for zirconia fixed dental prostheses (FDPs) may be a clinical limitation due to limited space in the occlusogingival direction. Using no veneering in the gingival regions of the pontics and connectors may solve this problem. This study evaluated the mechanical durability of zirconia FDPs with and without veneering in the gingival area of the connectors and pontics and subsequent airabrasion of this region with different protocols. Models were made of resin abutments (diameter = 6 or 8 mm, height = 6 mm, 6 degrees convergence) and embedded in polyurethane resin (distance = 11 mm). Zirconia frameworks were milled and randomly distributed by veneering (veneering of the entire framework [VEN] or no veneering at gingival regions of the pontic and connector [NVEN]) and by air-abrasion (Al2O3/SiO2, 30 μm; or 45 μm Al2O3. FDPs were adhesively cemented and subjected to mechanical cycling (1,200,000 cycles, 200 N, 4 Hz, with water cooling). Specimens were tested until fracture (1 mm/min), and failure modes were classified. Data (N) were subjected to one-way analysis of variance in two sets, Tukey test (α = .05) and Weibull analysis. While veneering did not significantly affect the results (VEN: 1,958 ± 299 N; NVEN: 1,788 ± 152 N; P = .094), air abrasion did (P = .006), with the worst results for the groups conditioned with 45 μm Al2O3 (SiO2: 1,748 ± 273 N; Al2O3: 1,512 ± 174 N). The NVEN group demonstrated the highest Weibull modulus (12.8) compared with the other groups (5.3–7.2). Fractures commonly initiated from the gingival side of the connector. Veneering of the gingival region of the connectors and pontics in zirconia FDPs did not diminish the fracture strength, but air-abrasion of this area with 45 μm Al2O3 decreased the results.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help